You might want to think about employing a CTI certified business to produce your own, onsite performance figure. As somebody that designed hundreds of main utility plants I saw this cheating could sum from 20% to as high as 50% of the outlined functionality. Prior to CTI getting shaped all the cooling tower manufacturers cheated-to changing levels.

Supposing you get this details you require to furthermore get a dubious eyesight at the information. RE: BAC cooIing tower information (Mechanical) 20 December 06 23:16. Thank you in progress if you could find performance details for á BAC VST-325A (or related) cooling towér. The stock (therefore I've been informed) scanned their old catalogs, after that discarded them however, the scanned performance graphs I've gotten from them are usually unreadable.
#Bac cooling tower serial number age manual#
« Write-up by Admin - » Comménting on BAC Yóu content is usually one of the numerous benefits of becoming a associate of The Cycle, to sign-up today.ĭoes anyone have accessibility to an older Baltimaore Air flow Coils (BAC) selection manual (publication) for a VS series cooling tower? I'michael attempting to recommission a 1974 classic VST cooling tower and have got been unable to track down overall performance data for it. Number and serial number of the unit are also located in this area. Contact your local BAC Representative whose name and. Series 3000 and XE-Series Cooling Towers. SERIAL NUMBER NOMENCLATURE Prior to 1980 Apto June 1,1980 Jto Current 123456 A D 123 D A 123456 123 H 02. If you’re not familiar with the term Marketing Communications, you could say I’m the Company’s liaison to the social media world. Welcome to BAC You! Welcome to BAC You! I’m Chris Walton, Supervisor Marketing Communications at The Baltimore Aircoil Company for the last 11 years. Therefore please talk to us and let us know what't on your brain. Please deliver us questions - and I hope you perform! We possess a extremely theoretically savvy team addressing “HoweKool” and we are usually excited to assist you find the answers you are looking for.

#Bac cooling tower serial number age free#
Please feel free to remark on what l or any óf the others have to state. We wish to give you a appearance into who we are usually, what we perform and how we can help you in the potential. This will be our first Company blog page - but definitely not really our final. This blog provides us an chance to talk about some of those tales with you. Over the last 10 years, we have got encountered numerous modifications in the way we communicate with our customers, representatives and workers and its effect on our business. If you're not acquainted with the phrase Marketing Communications, you could say I'meters the Company's liaison to the social media world. Something to also consider is IF you change the fill, PVC distribution system, DE's, and shaft/bearing-then you might want to look at how much a new tower would cost.22 Scar Like to BAC You! I'd Chris Walton, Boss Marketing Marketing communications at The Baltimore Aircoil Organization for the final 11 yrs. Make sure the fans haven't seized and are also in good shape. I think BAC later offered a split shaft design to make these kind of repairs easier-so check into this. Changing the bearings is a flat pain in the butt-so check these before you fire it up. The longer cells have a motor at one end and as many as three bearings supporting the shaft/fans. Check to make sure they are still in good shape.īig thing to evaluate is the bearings and drive shaft and condition of the fans. Many of the VT's had the DE's mounted on top of the cells and made from a heavy galavanized steel. You might want to consider what are called cellular drift eliminators (DE's)-as they have lower pressure drop and are much more efficient wringing water out of the airstream.

The fill they use is adequate but their drift eliminators are poor. The spray headers are fairly straight forward and the nozzles BAC sells are decent. However, the lone applications where they shine over induced draft towers is ducted units and cold environments (both of which we only see in very cold environments like yours). I'm not a fan of the forced draft style towers mainly due to HP considerations and basin leaks.